Common Issues and Maintenance Methods for Tow Trucks

24m Articulated Bucket Lift Truck (2)

Regular maintenance of tow trucks is essential for ensuring reliable performance and preventing breakdowns. Here’s a guide to common issues and their solutions:

SHACMAN H3000 21 Ton Knuckle Boom Garabia (4)

  1. Slow or Weak Boom Extension
    • Causes:
      1. Hydraulic power system issues
      2. Malfunctioning extension mechanism control or relief valve
    • Solutions:
      1. Inspect and adjust the hydraulic system
      2. Disassemble, clean, and replace faulty components
  2. Boom Extension Vibrations
    • Causes:
      1. Worn or damaged boom slide blocks
      2. Issues with telescoping cylinders
    • Solutions:
      1. Apply grease to slide surfaces and replace or repair damaged slide blocks
      2. Inspect and rectify issues with the telescoping cylinders
  3. Inability to Compensate for Boom Extension Lengths
    • Causes:
      1. Faulty solenoid valve
      2. Circuit malfunctions
    • Solutions:
      1. Clean the filter and replace the solenoid valve
      2. Diagnose and repair any circuit faults
  4. Automatic Boom Retraction
    • Causes:
      1. Defective telescoping cylinder
      2. Malfunctioning balancing valve
    • Solutions:
      1. Inspect and adjust or replace the telescoping cylinder
      2. Check and repair the balancing valve
  5. Lift Mechanism Not Operating or Operating Slowly
    • Causes:
      1. Faulty control valve
      2. Malfunctioning hydraulic motor
      3. Defective balancing valve
      4. Faulty lift brake
    • Solutions:
      1. Repair or replace the control valve
      2. Service or replace the hydraulic motor
      3. Inspect and repair the balancing valve
      4. Adjust or replace the lift brake components
  6. Intermittent Movement of the Lift Mechanism
    • Causes:
      1. Faulty one-way valve
    • Solutions:
      1. Clean or replace the one-way valve
  7. Loss of Load Control During Hook Release
    • Causes:
      1. Malfunctioning balancing valve
    • Solutions:
      1. Disassemble and clean the balancing valve
  8. Lift Mechanism Brake Not Opening
    • Causes:
      1. Jammed shuttle valve
      2. Internal leakage in shuttle valve
      3. Poor sealing of the brake piston
    • Solutions:
      1. Repair or replace the shuttle valve
      2. Fix internal leakage issues
      3. Repair or replace the brake seals
  9. Over-limit Lifting or Over-winding Alarm Not Working
    • Causes:
      1. Faulty alarm system
      2. Defective over-winding relay
    • Solutions:
      1. Repair or replace the alarm system and over-winding relay
  10. Boom Extension Cylinder Automatically Retracting
    • Causes:
      1. Faulty cylinder
      2. Malfunctioning balancing valve
    • Solutions:
      1. Inspect and address cylinder issues
      2. Disassemble, clean, and replace faulty components in the balancing valve
  11. Boom Extension Cylinder Vibrations
    • Causes:
      1. Air trapped in the cylinder
      2. Improperly adjusted or damaged balancing valve
    • Solutions:
      1. Bleed air from the cylinder by performing multiple extension actions with no load
      2. Adjust or replace the balancing valve and inspect for blockages
  12. Jacks Not Extending or Retracting
    • Causes:
      1. Faulty bidirectional hydraulic lock
    • Solutions:
      1. Inspect and repair the bidirectional hydraulic lock
  13. Automatic Retraction of Jacks During Lifting
    • Causes:
      1. One-way valve failure in the bidirectional hydraulic lock
      2. Poor valve sealing
      3. Internal leakage in the cylinder
    • Solutions:
      1. Repair or replace the one-way valve
      2. Address issues with valve sealing and repair cylinder leaks
  14. No Action or Slow Action During Lifting
    • Causes:
      1. Faulty hydraulic pump
      2. Defective relief valve
      3. Damaged rotary joint
      4. Faulty manual control valve
    • Solutions:
      1. Inspect and repair the hydraulic pump, relief valve, and rotary joint
      2. Repair or replace the manual control valve
  15. Excessive Oil Temperature
    • Causes:
      1. Malfunctioning hydraulic pump
      2. Contaminated or insufficient hydraulic oil
    • Solutions:
      1. Repair or replace the hydraulic pump
      2. Replace or top up the hydraulic oil and ensure it’s clean
  16. Hydraulic Pump Not Rotating
    • Causes:
      1. Power take-off or control air circuit failure
    • Solutions:
      1. Inspect, repair, or replace the power take-off and control air circuit
  17. High Return Line Pressure
    • Causes:
      1. Clogged filter
    • Solutions:
      1. Replace the filter element
  18. Hydraulic Oil Leakage
    • Causes:
      1. Damaged seals
      2. Issues with pipe connections
      3. Damaged pipes
    • Solutions:
      1. Replace damaged seals
      2. Tighten or replace pipe fittings
      3. Replace damaged pipes
  19. Poor Electrical Contact in the Rotary Joint
    • Causes:
      1. Poor contact between brushes and slip rings
      2. Broken wire connections
    • Solutions:
      1. Repair electrical connections
      2. Fix or replace broken wire connections
  20. Loud Noise in the Hydraulic System
    • Causes:
      1. Air in the hydraulic lines
      2. Low oil temperature
      3. Loose or poorly secured pipes and components
      4. Faulty balancing valve
      5. Clogged filter
      6. Insufficient oil in the tank
    • Solutions:
      1. Bleed air from the hydraulic lines by performing multiple operations
      2. Operate the pump at low speed to warm up the oil or replace it
      3. Tighten loose connections and ensure no air leaks
      4. Adjust or replace the balancing valve
      5. Clean or replace the filter element

SHACMAN M3000 21 Ton Knuckle Boom Garabia (5)

Regular inspection and prompt resolution of these issues will help keep your tow truck in optimal working condition, ensuring reliability and safety during operations.

Erantzun bat utzi

Zure helbide elektronikoa ez da argitaratuko. Beharrezko eremuak markatuta daude *